Commercial Grade Ground Fault Receptacle, 15 Amps, 125 Volts, Ivory, NEMA 5-15R
(Pack of
1)
SKU:15507 Item#: 15507
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Frequently Bought Together
Miniature Incandescent Bulb 12V 2CP
$0.00
Couldn't load pickup availability
Miniature Incandescent Bulb 12V 12CP
$0.00
Couldn't load pickup availability
Miniature Incandescent Bulb 12V
$0.00
Couldn't load pickup availability
Thermoplastic Plug 2 Pole 3 Wire 15A 125V
$0.00
Couldn't load pickup availability
Industrial Duty Connector 15A 125V
$0.00
Couldn't load pickup availability
Industrial Duty Duplex Receptacle 15A 125V Brown
$0.00
Couldn't load pickup availability
Fender Splash Shield Push Rivet Nylon 7mm Hole
$0.00
Couldn't load pickup availability
Specialty Rivet with Plastic Cap Aluminum 3.2mm
$0.00
Couldn't load pickup availability
Inner Fender Shield Attaching Clip Nylon Black
$0.00
Couldn't load pickup availability
Locking Receptacle 20A 250V
$0.00
Couldn't load pickup availability
Thermoplastic Connector 2 Pole 3 Wire 15A 125V
$0.00
Couldn't load pickup availability
Toggle Switch SPST 20A 12V Off-White/On-Red
$0.00
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15507 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-15R |
| Color | Ivory |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.37 lb |