Commercial Grade Ground Fault Receptacle, 15 Amps, 125 Volts, White, NEMA 5-15R
(Pack of
1)
SKU:15508 Item#: 15508
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Frequently Bought Together
Miniature Incandescent Bulb 12V 36CP
Couldn't load pickup availability
Miniature Incandescent Bulb 12V
Couldn't load pickup availability
Miniature Incandescent Bulb 12V 37CP
Couldn't load pickup availability
Weather Protected Connector Boot 2 Pole 3 Wire 30A
Couldn't load pickup availability
Industrial Duty SAF-T Connect Connector 20A 125V
Couldn't load pickup availability
Locking Connector 2 Pole 3 Wire 20A 250V
Couldn't load pickup availability
Front Bumper Specialty Nut Steel M4.2-1.41
Couldn't load pickup availability
Shield Push-Type Retainer with Metal Insert
Couldn't load pickup availability
Acrysol Paint Preparation and Auto Body Solvent
Couldn't load pickup availability
Sealed Toggle Switch SPDT 18A 125V On-None-On
Couldn't load pickup availability
Push-Pull Switch SPST 15A 12V Off-On
Couldn't load pickup availability
Industrial Duty Duplex Receptacle 15A 125V Brown
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15508 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-15R |
| Color | White |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.37 lb |