Commercial Grade Ground Fault Receptacle, 15 Amps, 125 Volts, White, NEMA 5-15R
(Pack of
1)
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Couldn't load pickup availability
California Proposition 65: Not Applicable
www.P65Warnings.ca.gov
Frequently Bought Together
Nylon Cable Tie 5-1/2" Black
Couldn't load pickup availability
Heat Shrink Tubing 20 to 16 AWG Black
Couldn't load pickup availability
Procell AAA Alkaline Battery 1.5V
Couldn't load pickup availability
Toggle Switch AC Single Pole 15A 120V Brown
Couldn't load pickup availability
Industrial Duty Connector 20A 125V
Couldn't load pickup availability
Industrial Duty Connector 20A 125V
Couldn't load pickup availability
Air Distributor Defroster Push-Type Retainer
Couldn't load pickup availability
Nylon Cable Tie 11-3/4" Black
Couldn't load pickup availability
Bumper Drive Rivet Plastic 10mm Hole
Couldn't load pickup availability
Rocker Switch SPST 25A 12VDC Off-On
Couldn't load pickup availability
Rocker Switch Bracket for End Unit
Couldn't load pickup availability
Sealed Toggle Switch DPDT 18A 125V On-Off-On
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15508 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-15R |
| Color | White |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.37 lb |
Product Restrictions
California Proposition 65: Not Applicable
www.P65Warnings.ca.gov