AJT Series Class JT Indicator Fuse, 500 Amps, 600 Volts, Time Delay
(Pack of
1)
SKU:1325078 Item#: 1325078
Indicator fuses provide visual blown fuse indication at a glance
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Interrupting rating: 200,000A rms symmetrical; 300,000A rms symmetrical (UL listed Special Purpose) UL listed Class J Fuses per UL 198C CSA certified HRCI-J per C22.2 #106 Meets Federal Specification WF1814 (QPL)
Provide space-saving protection for service entrance, main, feeder and general-purpose branch circuits
Time-delay characteristics and high current limitation mean the JTD fuse is also used in the protection of circuits with high-inrush currents such as motors, transformers and solenoids, including both IEC-rated and NEMA-rated devices
Fuses 100A and higher have blade ends
Frequently Bought Together
Ring Tongue Terminal 16 to 14 AWG Blue
$0.00
Couldn't load pickup availability
Butt Connector 12 to 10 AWG Yellow
$0.00
Couldn't load pickup availability
Rechargeable Neck Light
$0.00
Couldn't load pickup availability
Universal Plug-In Circuit Breaker Type I 10A
$0.00
Couldn't load pickup availability
MCaseâ„¢ Cartridge Fuse 15A Gray
$0.00
Couldn't load pickup availability
ATO/ATC In-Line Fuse Holder with Cap 32V 25-35A
$0.00
Couldn't load pickup availability
A6DR Series Class RK1 Indicator Fuse 60A
$0.00
Couldn't load pickup availability
KTK Series Midget Fuse 1/4A
$0.00
Couldn't load pickup availability
326 Series Ceramic Body Fuse 1-2/10A
$0.00
Couldn't load pickup availability
Front Bumper Push-Type Retainer Nylon 10mm
$0.00
Couldn't load pickup availability
Nylon Cable Tie 15-1/4" Black
$0.00
Couldn't load pickup availability
Rocker Door and Exterior Molding Retainer
$0.00
Couldn't load pickup availability
Product Description
Indicator fuses provide visual blown fuse indication at a glance Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Interrupting rating: 200,000A rms symmetrical; 300,000A rms symmetrical (UL listed Special Purpose) UL listed Class J Fuses per UL 198C CSA certified HRCI-J per C22.2 #106 Meets Federal Specification WF1814 (QPL)
Provide space-saving protection for service entrance, main, feeder and general-purpose branch circuits
Time-delay characteristics and high current limitation mean the JTD fuse is also used in the protection of circuits with high-inrush currents such as motors, transformers and solenoids, including both IEC-rated and NEMA-rated devices
Fuses 100A and higher have blade ends
Technical Specifications
| Item#: | 1325078 |
|---|---|
| Manufacturer Model #: | AJT500 |
| Fuse Class | JT |
| Amperage | 500 A |
| Volts | 600 |
| Activation Type | Time-Delay |
| Manufacturer Designation | AJT |
| UNSPSC #: | 39121627 |
| TAA Compliant: | Yes |