Kup-L-Tap Connector-250-500 MCM AWG (Main), 4 AWG-250 MCM (Tap), 600 Volts, 2.9" Width, 3.75" Height, 2.42" Depth
(Pack of
1)
SKU:97762 Item#: 97762
Installs faster than any other cable tap
Body is tough, resilient glass-filled nylon
Factory-installed silicone lubricating compound fills voids, keeping contamination out
Bolts and top and bottom plates are fully insulated from the conductor and contact teeth by molded nylon sleeves
Extra hard tin-coated copper contact teeth easily penetrate most types of insulation no cable stripping required
Dual-rated for copper and aluminum conductors
Can be installed on energized conductor
Requires no cover or tape
Runs cooler than the conductor
Bolt tightens with just a wrench
A horizontal line grid provides a visual guide for proper installation of conductors
Installation Instructions1. Loosen connector bolt(s) and separate halves.2. Mount the main cable in the main groove of the connector by placing the connector halves over the cable.3. Insert the squared-off tap cable into the tap groove until it contacts the end tab. Tighten the bolt(s) until securely fastened.4. Completed installation.
Frequently Bought Together
Specialty Rivet with Plastic Cap Aluminum 3.2mm
$0.00
Couldn't load pickup availability
Inner Fender Shield Attaching Clip Nylon Black
$0.00
Couldn't load pickup availability
Front Fender Liner Push-Type Retainer Nylon 20mm
$0.00
Couldn't load pickup availability
Product Description
Installs faster than any other cable tap Body is tough, resilient glass-filled nylon
Factory-installed silicone lubricating compound fills voids, keeping contamination out
Bolts and top and bottom plates are fully insulated from the conductor and contact teeth by molded nylon sleeves
Extra hard tin-coated copper contact teeth easily penetrate most types of insulation no cable stripping required
Dual-rated for copper and aluminum conductors
Can be installed on energized conductor
Requires no cover or tape
Runs cooler than the conductor
Bolt tightens with just a wrench
A horizontal line grid provides a visual guide for proper installation of conductors
Installation Instructions1. Loosen connector bolt(s) and separate halves.2. Mount the main cable in the main groove of the connector by placing the connector halves over the cable.3. Insert the squared-off tap cable into the tap groove until it contacts the end tab. Tighten the bolt(s) until securely fastened.4. Completed installation.
Technical Specifications
| Item#: | 97762 |
|---|---|
| Wire Range Main | 250-500 MCM |
| Wire Range Tap | 4-250 MCM |
| Volts | 600 |
| Length | 2.42 " |
| Width | 2.9 " |
| Height | 3.75 " |
| Depth | 2.42 " |
| Torque Recommendation | 55 lb |
| Approvals | UL, CSA |
| Style | Kup-L-Tap |
| Type | Electrical Connectors |
| UNSPSC #: | 39121409 |
| TAA Compliant: | Yes |
| Weight: | 1.05 lb |