Kup-L-Tap Connector, 4 to 4/0 AWG Main, 14 to 6 AWG Tap, 1" Width, 1.42" Depth
(Pack of
1)
SKU:97756 Item#: 97756
Installs faster than any other cable tap
Body is tough, resilient glass-filled nylon
Factory-installed silicone lubricating compound fills voids, keeping contamination out
Bolts and top and bottom plates are fully insulated from the conductor and contact teeth by molded nylon sleeves
Extra hard tin-coated copper contact teeth easily penetrate most types of insulation no cable stripping required
Dual-rated for copper and aluminum conductors
Can be installed on energized conductor
Requires no cover or tape
Runs cooler than the conductor
Bolt tightens with just a wrench
A horizontal line grid provides a visual guide for proper installation of conductors
Installation Instructions1. Loosen connector bolt(s) and separate halves.2. Mount the main cable in the main groove of the connector by placing the connector halves over the cable.3. Insert the squared-off tap cable into the tap groove until it contacts the end tab. Tighten the bolt(s) until securely fastened.4. Completed installation.
Couldn't load pickup availability
Frequently Bought Together
Miniature Incandescent Bulb 12V 32CP
$0.00
Couldn't load pickup availability
Miniature Incandescent Bulb 12V
$0.00
Couldn't load pickup availability
Miniature Incandescent Bulb 12V
$0.00
Couldn't load pickup availability
Kup-L-Tap Connector 8 to 1/0 AWG Main
$0.00
Couldn't load pickup availability
Fender Bumper Shield Retainer 11/16"
$0.00
Couldn't load pickup availability
Front Bumper Drive Rivet Plastic 10mm Hole
$0.00
Couldn't load pickup availability
Front Bumper Drive Rivet Plastic 7mm Hole
$0.00
Couldn't load pickup availability
Male Quick Slide Terminal 22 to 18 AWG Red
$0.00
Couldn't load pickup availability
Ring Tongue Terminal 16 to 14 AWG Blue
$0.00
Couldn't load pickup availability
Step-Down Butt Connector 16 to 14/22 to 18 AWG Red
$0.00
Couldn't load pickup availability
Product Description
Installs faster than any other cable tap Body is tough, resilient glass-filled nylon
Factory-installed silicone lubricating compound fills voids, keeping contamination out
Bolts and top and bottom plates are fully insulated from the conductor and contact teeth by molded nylon sleeves
Extra hard tin-coated copper contact teeth easily penetrate most types of insulation no cable stripping required
Dual-rated for copper and aluminum conductors
Can be installed on energized conductor
Requires no cover or tape
Runs cooler than the conductor
Bolt tightens with just a wrench
A horizontal line grid provides a visual guide for proper installation of conductors
Installation Instructions1. Loosen connector bolt(s) and separate halves.2. Mount the main cable in the main groove of the connector by placing the connector halves over the cable.3. Insert the squared-off tap cable into the tap groove until it contacts the end tab. Tighten the bolt(s) until securely fastened.4. Completed installation.
Technical Specifications
| Item#: | 97756 |
|---|---|
| Wire Range Main | 4-4/0 |
| Wire Range Tap | 14-6 |
| Volts | 600 V |
| Width | 1 " |
| Height | 1.87 " |
| Depth | 1.42 " |
| Torque Recommendation | 13 lb |
| Approvals | UL, CSA |
| Style | Kup-L-Tap |
| Type | Electrical Connectors |
| UNSPSC #: | 39121409 |
| TAA Compliant: | No |
| Weight: | 0.16 lb |