FLSR Series Class RK5 Indicator Fuse, 60 Amps, 600 Volts AC, 300 Volts DC, Time Delay
(Pack of
1)
Fuses provide visual blown fuse indication at a glance
Patented state-of-the-art solid state design provides maximum reliability and superior performance in a true dual-element design
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an FLNR_ID or FLSR_ID Indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Rated at 600V AC, 300V DC maximum
Interrupting ratings: AC 200,000A rms symmetrical, DC 20,000A
MSHA 300V DC listing
Couldn't load pickup availability
California Proposition 65: WARNING: Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
Frequently Bought Together
MINI Fuse 15A Blue
Couldn't load pickup availability
Lithium Battery #2450 3V
Couldn't load pickup availability
Butt Connector 22 to 24 AWG Clear
Couldn't load pickup availability
FLNR Series Class RK5 Indicator Fuse 80A
Couldn't load pickup availability
251 Series Pico II Fuse 3/4A
Couldn't load pickup availability
235 Series Glass Body Fuse 250mA
Couldn't load pickup availability
FLSR Series Class RK5 Indicator Fuse 6-1/4A
Couldn't load pickup availability
CCMR Series Class CC Fuse 2.5A
Couldn't load pickup availability
FLNR Series Class RK5 Indicator Fuse 2A
Couldn't load pickup availability
Shroud Insulating Button Nylon 11/16"
Couldn't load pickup availability
Front Bumper and Radiator Support Drive Rivet
Couldn't load pickup availability
Push-Type Retainer Nylon 20mm
Couldn't load pickup availability
Product Description
Fuses provide visual blown fuse indication at a glance Patented state-of-the-art solid state design provides maximum reliability and superior performance in a true dual-element design
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an FLNR_ID or FLSR_ID Indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Rated at 600V AC, 300V DC maximum
Interrupting ratings: AC 200,000A rms symmetrical, DC 20,000A
MSHA 300V DC listing
Technical Specifications
| Item#: | 60108 |
|---|---|
| Style | FLSR_ID Indicator Class RK5 Fuses |
| Amperage | 60 A |
| Rating | 600V AC, 300V DC maximum V |
| Type | Fuses |
| Replaces | competitors FRS-R and TRS-R non-indicating fusess |
| UNSPSC #: | 39121627 |
| TAA Compliant: | Yes |
| Weight: | 0.35 lb |
Product Restrictions
California Proposition 65: WARNING: Cancer and Reproductive Harm -