Commercial Grade Ground Fault Receptacle, 20 Amps, 125 Volts, Brown, NEMA 5-20R
(Pack of
1)
SKU:15509 Item#: 15509
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Frequently Bought Together
Lithium Battery #2450 3V
Couldn't load pickup availability
Super 33+ Series Vinyl Electrical Tape Black 3/4"
Couldn't load pickup availability
Energizer® AAA Alkaline Battery 1.5V
Couldn't load pickup availability
Wall Plate for Toggle Switch 302/302 SS
Couldn't load pickup availability
Industrial Duty Watertight Plug 20A 125V
Couldn't load pickup availability
Industrial Duty Watertight Connector 20A 125V
Couldn't load pickup availability
Air Distributor Defroster Push-Type Retainer
Couldn't load pickup availability
High-Tech Seam Sealer Clear 5fl.oz
Couldn't load pickup availability
Fender Splash Shield Retainer Nylon 20mm
Couldn't load pickup availability
Weather Protected Connector Boot 2 Pole 3 Wire 30A
Couldn't load pickup availability
Universal Sealed Toggle Switch SPDT 10A 115V
Couldn't load pickup availability
Industrial Duty SAF-T Connect Connector 20A 125V
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15509 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-20R |
| Color | Brown |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.33 lb |